Specification:
Standard: DIN75220,BMW306.4
Irradiation Intensity Range: 700-1100w/m2;
Typical temperature and humidity conditions:-40℃,85℃,85%RH;
Equipped with multiple temperature protection sensors to ensure the safe and stable operation of the system;
Industrial computer remote control
Touch-screen operation interface
Model |
GRO-V-SUN0808THL |
GRO-V-SUN2008THL |
GRO-V-SUN2016THL |
GRO-V-SUN2026THL |
GRO-V-SUN6025THL |
|
Temperature/humidity of environment while using |
+5~+35℃/≤80%RH |
|||||
Controller |
GRO-800 control instrument integrated Siemens S7 programmable controller |
|||||
Control Mode |
Independent cold and hot end PID adjustment, heat and cooling can be continuously adjusted. |
|||||
Parameter |
Irradiation Area (mm) |
800*600 |
2000*800 |
2000*1600 |
2000*2600 |
6000*2500 |
Irradiation Intensity |
600-1200 w/㎡ |
|||||
Spectral Range |
280-3000nm |
|||||
Spectral Range |
DIN75220、CIE85 |
|||||
Nonuniformity |
<±50W/㎡ |
|||||
Stability |
<±2% |
|||||
Temperature Range |
-40-120℃ |
|||||
Temperature Fluctuation |
≤±1.0℃ |
|||||
Temperature Deviation |
≤±2℃ |
|||||
Temperature Uniformity |
≤2℃ |
|||||
Humidity Range |
10-95%RH |
|||||
Humidity Fluctuation |
≤±2%RH |
|||||
Humidity Deviation |
≤±3%RH |
|||||
Temperature Rise/Fall Speed |
≥100℃/h or ≥200℃/h |
|||||
Interior Size |
W(mm) |
1000 |
2600 |
2600 |
2600 |
--- |
D(mm) |
1000 |
1400 |
2400 |
3200 |
--- |
|
H(mm) |
1000 |
2400 |
2400 |
2400 |
--- |
|
External Size |
W(mm) |
1600 |
2900 |
4000 |
5200 |
--- |
D(mm) |
2000 |
3600 |
5700 |
5700 |
--- |
|
H(mm) |
2800 |
3200 |
3200 |
3200 |
--- |
|
Condenser |
Air/Water |
Water |
Water |
Water |
Water |
|
Power Supply |
AC 380V 50Hz 3-phase+N+PE |
|||||
Maximum Current (A) |
50 |
120 |
180 |
240 |
700 |
|
Maximum Power (kw) |
32 |
80 |
120 |
160 |
400 |
|
Standard Equipment |
● Viewing Window ● Full Spectrum Sensor ● Temperature Sensor ● Humility Sensor ● Interior Lighting
● USB Port |
|||||
Optional Equipment |
○ External Outlet 220V 10A ○ Glass box ○ Cloud simulation system
○ Automatic scanning system Other non-standard configurations |
|||||
*Performance index is measured at room temperature of +25°C; The sensor is at the air outlet of the air handling unit. |