High temperature test chamber

This product is ideal for high temperature storage and processing

Model Unit: GROG

Function: high temperature testing

The maximum temperature can reach 300 °C; different volumes can be customized according to customer requirements;

It is also possible to customize a walk-in high temperature aging chamber;

Equipped with multiple temperature protection sensors to ensure safe and stable operation of the system;

The control system can be either touch screen or digital instrument

Model

GROG-216

GROG-512

GROG-800

GROG-1000

Power Supply

AC 380V 50Hz 3-phase+N+PE

Maximum Current (A)

16

16

24

30

Maximum Power (kw)

8

9

12

15

Temperature / humidity of environment while using

’+5+35/≤80%RH

Control Mode

Forced convection thermoregulation mode; independent hot-end PID adjustment, heat can be continuously adjusted

Parameter*1

Temperature Range

’RT+10+200

Temperature Fluctuation

’≤±0.5

Temperature Deviation

≤±2

Temperature Uniformity

≤2;(R.T.+10+150)
≤5
;(+150+200)

Controller

Digital display meter

Temperature adjustment method

Forced convection temperature regulation mode; independent hot-end PID regulation, heat can be continuously adjusted

Internal volume (Liters)

216

512

800

1000

Interior Size

W(mm)

600

800

1000

1000

D(mm)

600

800

800

1000

H(mm)

600

800

1000

1000

External Size

W(mm)

1300

1450

1700

1700

D(mm)

1200

1100

1100

1300

H(mm)

900

1000

1700

1700

Standard Equipment                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  

● Casters
● Partition
● Cable Hole with Silicone Plug Φ80mmx1

Optional Equipment

○ Cable Hole with Silicone Plug Φ25mm
○ Partition
○ External plug 220V 10A

*Performance index is measured at room temperature of +25°C; The sensor is at the air outlet of the air handling unit.