中文Language Search
Home > Products > Light Simulation Units > Solutions of Solar Industry > Steady-state solar temp rise test chamber
Light Simulation Units
< Back

Steady-state solar temperature rise test chamber

Specification:

Standard: IEC61730

Core Technical Features: Low Air Speed (≤0.25m/s), 
Irradiation Intensity Range: 700-1100w/m2

Various irradiation range can be customized according to customer requirements;

Equipped with multiple temperature protection sensors to ensure the safe and stable operation of the system;

Touch-screen control interface

Model

GRO-SUN1424T

GRO-SUN2424T

Temperature/humidity of environment while using

+5+35/≤80%RH

Controller

GRO-800 control instrument integrated Siemens S7 programmable controller

Control Mode

Independent cold and hot end PID adjustment, heat and cooling can be continuously adjusted.

Number of samples (Crystal silicon component 2000*1000mm)

1 hot spot,1 temperature rise

2 hot spot, 2 temperature rise

Parameter

Irradiation Area (mm)

1400*2400

2400*2400

Irradiation Intensity

600-1200w/m2

Spectral Range

400-1100nm

Spectral Matching

0.6~1.4 (B Level)

Nonuniformity

±5% (B Level)

Stability

±2% (A Level)

Temperature Range

30-80

Temperature Fluctuation

≤±1.0

Temperature Deviation 

≤±2 (No Load)

Sample Temperature Uniformity

≤±5

Air Speed (Temperature rise test)

≤0.25m/s

Air Speed (Hot spot test)

≤5m/s

Interior Size

W(mm)

3400

3400

D(mm)

2400

3400

H(mm)

2000

2000

External Size

W(mm)

4600

4600

D(mm)

3200

4200

H(mm)

2600

2600

Condenser

Water

Power Supply 

AC 380V 50Hz 3-phase+N+PE

Maximum Current (A)

75

90

Maximum Power (kw)

45

60

Standard Equipment                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              

● Viewing Window

● Sample Holder

● Full Spectrum Sensor

● Temperature Sensor

● Interior Lighting

● USB Port

● Cable Hole with Silicone Plug Φ80mmx1

Optional Equipment

○ External Outlet 220V 10A

○ Electronic Load

○ Automatic Scanning System
○ LAN interface and remote-control software

Other non-standard configurations

*Performance index is measured at room temperature of +25°C; The sensor is at the air outlet of the air handling unit.

Download PDF